Excerpt from an Enhanced Home Inspection

 

Insulation Missing - NW corner of the living room high ceiling: The insulation has been blown back from the hip roof eave end of the attic at the front of the residence. These could be insulation "shadows" from the truss chords during installation or from wind entering the frieze (ventilation) ports, aggravated by a possible lack of wind baffles.

Object Parameter

Value

Max (window frame - ignore)

88.9F

S1 typical insulated area

73.4F

S2 missing insulation

85.1F

S3 typical wall insulation

72.1F


Object Parameter

Value

File Name

IMAGE031.IRI

Emissivity

0.98

Humidity

30%

Distance

18

Ambient

78.0F

MaxTemp

88.9F

MinTemp

65.5F

Created Date

Sunday, September 16, 2007

Created Time

2:50:51 PM

Remark

IRI Image File Version:1.7

 

 

 

877-822-3252